Procedures · Gynae Procedures · Hysteroscopy

Operative hysteroscopy: polypectomy and resection of a submucous fibroid

Hysteroscopy treats lesions inside the cavity without an incision. Safety depends on three things: the right distension fluid for the energy used, constant measurement of the fluid deficit with agreed limits for stopping, and energy used only under a clear view. The 3D view shows the cavity with the uterus made see-through.

Draft guide, awaiting specialist review. Check against your unit's protocol.

Side view of the pelvis with the fluid bag and pump, and the fluid limits listed.
Step 1 of 5

Choose the fluid and set the limits

Match the distension fluid to the energy: saline with bipolar instruments, scissors or a morcellator; glycine, sorbitol or mannitol with a monopolar resectoscope. Use an automated pump that shows the deficit in real time and a drape that collects outflow. Agree the stopping deficit with the anaesthetist before starting, keep intrauterine pressure at about 70 to 80 mmHg, and aim to finish within an hour.

Pitfall. Saline cannot be used with a monopolar resectoscope, and a hypo-osmolar fluid allows far less absorption before it becomes dangerous.
Side view: the scope passes through the cervix and the cavity fills with fluid.
Step 2 of 5

Enter under vision and survey

With a tenaculum on the cervix, dilate only as far as the sheath needs. Pass the scope through the cervix under direct vision with fluid running, following the canal into the cavity. Identify both tubal ostia, then survey the cavity and the lesions. If the view is lost, pull back with the fluid running rather than pushing on.

Pitfall. Most perforations happen at entry. Overdilating makes fluid leak around the sheath and the cavity will not distend.
Side view: the polyp is cut free and comes out with the scope.
Step 3 of 5

Remove the polyp

Cut the polyp at its base with hysteroscopic scissors and grasp it with forceps, or take it with a twisting motion, a snare, the resectoscope loop or a morcellator. Withdraw the scope with the polyp and send it for histology. Coagulate any bleeding point with a ball electrode.

Pitfall. Blind polyp removal with forceps or curettage leaves residual polyp in many women. Remove it under vision.
Side view: the fibroid in the cavity shrinks as it is shaved.
Step 4 of 5

Shave the submucous fibroid

With the loop electrode on continuous (cutting) current, place it beyond the fibroid and activate it only while drawing it back towards the scope, shaving the fibroid down level with the surrounding myometrium. Remove the chips for histology. A morcellator does the same with suction and no loose chips. Watch the deficit throughout.

Pitfall. A large central fundal fibroid carries the highest risk of perforation. For fibroids of 3 to 5 cm, consider laparoscopy at the same time.
Side view: the scope goes through the top of the uterus and the cavity collapses.
Step 5 of 5

Recognise perforation and fluid overload

A sudden loss of distension with a collapsing cavity suggests perforation. Stop. If an energy device was active, inspect the abdomen by laparoscopy or laparotomy for bowel, bladder or vessel injury. If the deficit reaches the limit, stop, check the serum sodium urgently, give a loop diuretic, and manage severe hyponatraemia in ICU.

Pitfall. Women are more vulnerable than men to cerebral oedema from hyponatraemia. Never push on past the deficit limit to finish a resection.

Indications

  • Endometrial polyps causing bleeding or infertility
  • Submucous fibroids, FIGO type 0 and type 1 (type 1 under 3 to 5 cm)
  • Uterine septum, intrauterine adhesions, retained products or a lost IUD

Contraindications

  • Pregnancy; active cervical or pelvic infection
  • Type 2 and intramural fibroids are better removed laparoscopically or at laparotomy
  • Suspected endometrial cancer should be sampled and staged rather than resected

Consent: points to cover

  • Perforation (about 1 in 100 operative cases, often during dilatation) and the need for laparoscopy, especially with energy devices
  • Fluid overload; bleeding; infection (uncommon); incomplete resection and a second procedure
  • Cramping and spotting for 1 to 2 weeks; no intercourse or tampons for about a week
  • Fertility: wait 3 months after resecting a fibroid with an intramural part before trying to conceive

Equipment

  • Operative hysteroscope or resectoscope (bipolar with saline, or monopolar with glycine, sorbitol or mannitol); hysteroscopic morcellator
  • Automated fluid pump with real-time deficit; under-buttock collection drape
  • Scissors and grasping forceps; loop and ball electrodes
  • Misoprostol for a stenotic cervix; Pratt dilators; an intrauterine balloon for bleeding

Complications

  • Uterine perforation, with thermal injury to bowel or bladder if an energy device was active
  • Fluid overload, hyponatraemia and cerebral oedema with hypo-osmolar fluids
  • Gas or air embolism
  • Haemorrhage; infection; intrauterine adhesions

Exam pearls

  • Monopolar energy needs an electrolyte-free fluid (glycine, sorbitol, mannitol); bipolar works in saline
  • Stop at a deficit of 2,500 mL for isotonic fluids, 1,000 mL for hypo-osmolar fluids (750 mL if elderly or unwell)
  • CO2 is for diagnostic hysteroscopy only, from a hysteroscopic insufflator at under 100 mL/min, never a laparoscopic one
  • Enter under direct vision and do not overdilate the cervix
  • Activate the loop only while pulling it back towards the scope
  • Sudden loss of distension suggests perforation; after perforation with energy, inspect the abdomen
Test yourself. 8 questions on hysteroscopy.
Checked against: Te Linde's Operative Gynecology, 12th ed., Ch. 13 Hysteroscopy, pp. 236-243, 250-253 (Te Linde 12e (2020)). Animations are original Ardua drawings.
Practise questions